        M310A

        M310A.jpg

        FEATURES:

        Support battery, capacitor material research, half-cell, three-electrode, button battery, small-capacity battery and other research tests, 0~5V full range controllable.

        Supports precision research and testing with 0.01% voltage and current accuracy.

        Support high-rate fast charge research, 30C can achieve 0.01% capacity accuracy; 100C can reach 0.1% capacity accuracy.

        Support custom pulse test with a minimum pulse width of 2mS.

        Full coverage of the measurement records of the voltage, current, capacity, energy, efficiency, capacitance, internal resistance and other parameters required for the study.

        The device comes with UPS and storage to effectively prevent data loss and damage caused by downtime, sudden power failure, network failure, etc.


        M310A PERFORMANCE:

        ITEM

        INSTRUMENT PERFORMANCE

        Range

        Voltage

        5V (DC to -5V)*1

        Current

        100uA、1mA、10mA、100mA

        ACCURACY

        (SET,READ)

        Voltage

        ±0.01%RD±0.01%FS

        Current

        ±0.01%RD±0.01%FS

        No. of CHANNELs


        8Chl

        No. of STEPs


        1024

        TIME

        Accuracy

        ≤±5uS/S (Equipment autonomous control, no communication and other time delay errors)

        Min Step Time

        20mS

        Min Pulse Time

        2mS

        Sampling Interval

        ≤10mS*2

        INPUT IMPEDENCE


        10GΩ(INPUT BASE CURRENT < 0.5nA

        TEMPERATURE DRIFT


        ≤20ppm/

        RESPONSE TIME


        Current 0~90% ≤1mS; Current -90~90% ≤3mS

        DATA RECORD

        Sampling Rate

        100HzSampling interval 10mS*2

        Setting Method

        Interval time, Sampling rate, Interval current, Interval capacity, Interval voltage, Interval energy

        PROCESS CONTROL

        Work Mode

        REST/ CC / CV / CCCV / CRATE / CP / CR / CPULSE / CSLOPE / DC / DV / DCDV / DRATE / DP / DR / DPULSE / DSLOPE

        End Conditions

        TIME / VOLTAGE / CURRENT / POWER / CAPACITY / ENERGY / LOOPS / PHASE CYCLE

        Protective Function

        Power-off data protection, Net break protection

        User-defined safety: Over voltage, Under voltage, Over current, Over rate, Over capacity.

        FUNTION


        DCIR、Capacitance capacity calculation、Step pluse、Three-electrode testReference test)、DQ/DV

        OUTPUT


        Four electrodes (support reference electrode test)

        COMMUNICATION


        10/100M Ethernet(RJ45)、USB(Console)

        OPERATING ENVIRONMENT

        Temperature

        0~40℃(23±2Optimum accuracy

        Humidity

        90% No condensation

        POWER SUPPLY


        AC220V~±10% 50Hz / AC110V~±10% 60Hz,  40W *3

        EQUIPMENT SIZE


        1U  W*H*L:430*300*43.5(mm)

        Note:    1. The voltage range can be customized by 2~8V.

        2. The sampling rate can be customized to 1000Hz (sampling interval 1mS).

        3. For best test accuracy and safety, be sure to ground well. The machine needs to be warmed for 30 minutes before use.

        prev articleno more

        next articleG310A

        CLIENT

        SERVICE

        Consulting

        South China East China North China Central China Overseas Other

        Business Mailbox

        tech@whland.com

        Share to:

        Top
        久久综合九色综合色鬼狠狠色,日韩精品国产另类专区,亚洲五月天综合,天天综合网网欲色天天影视